| Sign In | Join Free | My infospaceinc.com | 
              
  | 
      
Place of Origin : China
Brand Name : FARADAY
Certification : CE, ISO9001
Model Number : SX460
MOQ : 10 sets
Price : USD65-95
Packaging Details : Standard export package with plywood case
Delivery Time : 7-10 days
Payment Terms : T/T OR L/C
Supply Ability : 2000 pcs/ month
Insulation class : H
Protection class : IP23
Wire winding : 100% copper wire
Color : Gray
Warranty period : 2 years or 2000 hours
OEM service : Available
Frequency : 50HZ/ 60HZ
Voltage : 190-690V
Bearing : single or double bearings
Phase : single or three phase
Power factor : 0.8 lagged or 1
Sea Port : Shanghai port
Specifications for Spare Parts for AC Alternator Generator-AVR SX460/SX440/MX321/MX341
  	1. Directly Manufacturer
  	2. AVR Automatic Voltage Regulator for 100% Copper wire AC Alternator 
  	3. OEM Service
  	4. CE/ISO Approved
  	5. 7-10 days lead time
  	
FARADAY 100% Copper Wire Three Phase AC Alternator 4 pole Generator6.5KW-32KW
FARADAY 100% Copper Wire Three Phase AC Alternator 2 pole Generator 10KW to 30KW
Alternator Features:
- Brushless, Synchronous AC Alternator, Easy operation and simple maintenance
- IP23, Insulation Class H Alternator
- Usage: As a electric power source matching diesel engines for lighting purpose in Town, Countryside, Work sites, Mountain and Pasture lands
- Drip-proof type
- 3 phase 4 wire type, Star connection
- 50HZ, 380V, 1500RPM as standard, also 60HZ can be made as customers’ requirement
- Certificate: CE/ISO9001
Operating conditions
  	Under the following environment, The generator could be continuous and rated running:
  	Above sea level: Not exceed 1000m
  	Cooling air temperature: 258~313K(-15 ℃~ 40 ℃)
  	Relative air damping: not exceed 90%
Alternator Specification:
3-PH, 50HZ@1500RPM, 400/230V(Also can be made according to customers’ special requirements)
|   				 Alternator Model  |   			  				 FD1-FD3  |   		
|   				 Power  |   			  				 8.1KVA to 250KVA  |   		
|   				 Exciter type  |   			  				 Brushless, Self excitation system  |   		
|   				 Power factor  |   			  				 0.8  |   		
|   				 Voltage adjust range  |   			  				 ≥3%  |   		
|   				 Voltage regulation NL-FL  |   			  				 ≤±0.3%  |   		
|   				 Insulation Grade  |   			  				 H  |   		
|   				 Protection Grade  |   			  				 IP23  |   		
AVR SX460 for FARADAY FD1-FD3 Series Alternator data for your reference:
|   				 Stamford AVR  |   			  				 SX460  |   		
|   				 Sensing voltage  |   			  				 jumper selectable120(95-132)VAC, 240(190-264)VAC, single phase 2wire  |   		
|   				 Frenquency  |   			  				 50-60Hz nominal  |   		
|   				 Voltage Input  |   			  				 Max 90VDC at 207VAC input  |   		
|   				 Resistance  |   			  				 15 Ω minimum  |   		
|   				 Regulation  |   			  				 <±1% RMS with 4% engine governing  |   		
|   				 Voltage Build-up  |   			  				 residual voltage at avr terminal >5vac  |   		
|   				 External Voltage Adjustment  |   			  				 :+/-7% with 1k ohm 1 watt trimmer  |   		
|   				 Generator Power  |   			  				 <200kw  |   		
Product Show
  	
Package Details
  	
Warranty Period
- Within 24 months from alternator's delivery or 18 months after the date first used, whichever comes first.
- During the guarantee period, we will supply freely service of the easy damaged parts for the possible problems except for the incorrect operation.
- After expiration, you should pay for the spare parts cost for alternator maintenance.
Payment Terms
- 30% deposit(T/T),balance (70%) to be paid before shipment.
- 100% irrevocable L/C at sight.
Why Choose Us?
1) factory photos. Welcome to visit our factory!
- Over 12 years experience in generator field
- Directly manufacturer
  	
2) Production Process
  	
  	
New photos will come soon!

Main Partners
  	
How to choose us?
1.Classification of generator:
(1) single phase or three phase;
(2) single bearing or double bearing;
(3) PMG is optional (except for FD1 series)
(4) Droop Kit and Anti-condensation heater are optional according to the operation environment.
(5) 2 pole/ 4 pole/ 6 pole/ 8 pole alternators are optional
2.How to choose AVR?
FD1/FD2 series SX460
FD3/FD4/FD5 series SX440
FD6 SX321 / PMG
FD7 SX341 / PMG
3.How to select generator?
-- working environment (less than 1000m above sea level & less than 40 ℃ ambient temperature)
-- different country with different frequency (60HZ for Korea, Taiwan, Philippines, Saudi Arabia, North America and South America countries)
-- For sea side operating environment, anti-condensation heater and droop CT
-- Insulation class H generator
-- 2/3 pitch
-- silicon steel, 100% copper wire, VPI system with Elantas Epoxy insulation painting
4. What is FD and FDH?
--FD means Faraday low voltage alternator
--FDH means Faraday high voltage alternator
--The model instruction is as follows:
  	
| 
                                             | 
                
                        Spare Parts for AC Alternator Generator-AVR SX460/SX440/MX321/MX341 Images |